VDE 0250 Part 605, VDE 0295, EN 60228 Flame Retardant according to IEC/EN 60332-1-2 Halogen Free according to IEC/EN 60754-1/2

CHARACTERISTICS

Voltage Rating Uo/U : 3.6/6kV | 6/10kV

Test Voltage 3.6/6kV: 11kV | 6/10kV: 17kV

Ambient Temperature : Fixed: -40°C to +80°C Flexed: +5°C to +80°C

Minimum Bending Radius : Fixed: 6 x overall diameter Flexed: 10 x overall diameter

CONSTRUCTION

Phase Conductor : Class 5 copper

Insulation :Rubber compound

Semi-Conductive Layers : Semi-conductive tape over the conductor and inner and outer semi-conductive rubber layer on the insulation

Protective Earth Conductor : Individual copper screen

Control Conductor : Class 5 tinned copper

Central Filler : Rubber compound on a textile polyester support

First Inner Sheath : LSZH (Low Smoke Zero Halogen)

Monitoring Conductor : Copper wire screen over the first inner sheath

Second Inner Sheath : LSZH (Low Smoke Zero Halogen)

Armour : Steel wire braid over the second inner sheath

Outer Sheath : LSZH (Low Smoke Zero Halogen)

Sheath Colour : Black

SepehranCable.COM| خرید سیم و کابل سپهران کابل

DIMENSIONS

For AMBIENT TEMPERATURE other than 30°C (DE-RATING FACTOR at 30°C = 1)

VOLTAGE
kV
NO. OF CORES (PHASE + EARTH
+ CONTROL+ÜL)
NOMINAL CROSS  SECTIONAL AREA
mm2
CONDUCTOR DIAMETER
mm
MINIMUM OVERALL DIAMETER
mm
MAXIMUM OVERALL DIAMETER
mm
MAXIMUM TENSILE LOAD
N
NOMINAL WEIGHT
kg/km
VOLTAGE
kV
NO. OF CORES (PHASE + EARTH
+ CONTROL+ÜL)
NOMINAL CROSS  SECTIONAL AREA
mm2
CONDUCTOR DIAMETER
mm
MINIMUM OVERALL DIAMETER
mm
MAXIMUM OVERALL DIAMETER
mm
MAXIMUM TENSILE LOAD
N
NOMINAL WEIGHT
kg/km
Phase N Conductor Earth Conductor Control Conductor
3.6/6 3+3+3+ÜL 25 25/3E 2.5ST 6/1 47/2 52/1 1125 4120
3.6/6 3+3+3+ÜL 35 25/3E 2.5ST 7/2 49 54 1575 4570
3.6/6 3+3+3+ÜL 50 25/3E 2.5ST 8/9 52/5 57/8 2250 5300
3.6/6 3+3+3+ÜL 70 35/3E 2.5ST 10/6 56/1 61/6 3150 6370
3.6/6 3+3+3+ÜL 95 50/3E 2.5ST 12/3 60/3 66/2 4275 7600
3.6/6 3+3+3+ÜL 120 70/3E 2.5ST 13/8 63/8 70 5400 8990
3.6/6 3+3+3+ÜL 150 70/3E 2.5ST 15/5 67/2 73/7 6750 10130
6/10 3+3+3+ÜL 25 25/3E 2.5ST 6/1 47/2 52/7 1125 4160
6/10 3+3+3+ÜL 35 25/3E 2.5ST 7/2 49 54/6 1575 4610
6/10 3+3+3+ÜL 50 25/3E 2.5ST 8/9 52/5 58/4 2250 5340
6/10 3+3+3+ÜL 70 35/3E 2.5ST 10/6 56/1 62/2 3150 6410
6/10 3+3+3+ÜL 95 50/3E 2.5ST 12/3 60/3 66/8 4275 7640
6/10 3+3+3+ÜL 120 70/3E 2.5ST 13/8 63/8 70/7 5400 9030
6/10 3+3+3+ÜL 150 70/3E 2.5ST 15/5 67/2 74/4 6750 10170

CURRENT CARRYING CAPACITY

NOMINAL CROSS SECTIONAL AREA
mm2
LAYING ON THE FLOOR
Amps
FREE IN AIR
Amps
REELED
Amps
NOMINAL CROSS SECTIONAL AREA
mm2
LAYING ON THE FLOOR
Amps
FREE IN AIR
Amps
REELED
Amps
1 Layer 2 Layer 3 Layer 4 Layer 5 Layer 6 Layer 7 Layer
25 131 138 105 80 64 55 50 35 29
35 162 170 130 99 79 68 62 44 36
50 202 212 162 123 99 85 77 55 44
70 250 263 200 153 123 105 95 68 55
95 301 316 241 184 147 126 114 81 66
120 352 370 282 215 172 148 134 95 77
150 404 424 323 246 198 170 154 109 89
Ambient temperature of 30°C                

VOLTAGE DROP

NOMINAL CROSS SECTIONAL AREA
mm2
POWER FACTOR
NOMINAL CROSS SECTIONAL AREA
mm2
POWER FACTOR
0/7 0/8 0/9 1
25 1/29 1/45 1/6 1/71
35 0/95 1/06 1/16 1/23
50 0/69 0/77 0/83 0/87
70 0/51 0/56 0/6 0/61
95 0/41 0/45 0/47 0/47
120 0/34 0/36 0/38 0/36
150 0/29 0/31 0/32 0/29

DE-RATING FACTORS

For AMBIENT TEMPERATURE other than 30°C (DE-RATING FACTOR at 30°C = 1)

AMBIENT TEMPERATURE 15ºC 20ºC 25ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC
AMBIENT TEMPERATURE 15ºC 20ºC 25ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC
DE-RATING FACTOR 1/12 1/08 1/04 0/96 0/91 0/87 0/82 0/76 0/71