H01N2-D EN 50525-2-81 Welding Cable

APPLICATION

این کابل ها به عنوان اتصالی به ربات های جوشکاری در صنعت خودروسازی، کارخانه های کشتی سازی و خطوط دستی/خودکار و جوش نقطه ای استفاده می شوند. این کابل ها برای استفاده به عنوان کابل باتری اتصال دهنده یا در سیستم های ذخیره سازی باتری ایده آل هستند. ساختار محکم کابل آن ها را در برابر دماهای پایین و بالا، ازن و تشعشع، روغن ها، اسیدها، چربی ها و بنزین ها مقاوم می کند.

STANDARDS

EN 50525-2-81, EN 60228, HD 22.6, VDE 0282-6, BS 638 Part 4 Flame Retardant according to IEC/EN 60332-1-2

CHARACTERISTICS

Voltage Rating : 100V

Temperature Rating : Fixed: -40°C to +85°C Flexed: -20°C to +85°C

Minimum Bending Radius : Fixed: 6 x overall diameter

CONSTRUCTION

Conductor : Generally to Class 6 flexible copper conductor

Separator :PET (Polyester Tape)

Sheath :Rubber compound

Sheath Colour :Black Red

DIMENSIONS

NO. OF CORES NOMINAL CROSS
SECTIONAL AREA
mm2
NOMINAL THICKNESS OF INSULATION
mm
NOMINAL OVERALL DIAMETER
mm
NOMINAL WEIGHT
kg/km
1 10 2 9 146
1 16 2 10 204
1 25 2 11/5 290
1 35 2 12/5 384
1 50 2/2 14/5 535
1 70 2/4 16/5 716
1 95 2/6 18/5 943
1 120 2/8 20/5 1235
1 150 3 23 1556
 

CONDUCTORS

Flexible Copper Conductors for Single Core Cables

NOMINAL CROSS SECTIONAL AREA
mm2
MAXIMUM DIAMETER OF WIRES IN CONDUCTOR
mm
MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km
Plain Wires
10 0/21 1/91
16 0/21 1/21
25 0/21 0/78
35 0/21 0/554
50 0/21 0/386
70 0/21 0/272
95 0/21 0/206
120 0/51 0/161
150 0/51 0/129
 

ELECTRICAL CHARACTERISTICS

Current Carrying Capacity

NOMINAL CROSS SECTIONAL AREA
mm2
CURRENT RATING FOR SINGLE CYCLE OPERATION OVER A MAXIMUM PERIOD OF 5 MINUTES
Amps
100% 85% 60% 35%
10 100 103 108 122
16 135 145 175 230
25 180 195 230 300
35 225 245 290 375
50 285 305 365 480
70 355 385 460 600
95 430 470 560 730
120 500 540 650 850
150 580 630 750 980

Ambient Air Temperature: 25°C Maximum Conductor Temperature: 85°C 

Duty Cycle and Current Carrying Capacity
The current carrying capacity of a welding cable depends on the length of the duty cycle. The duty cycle is the length of time during which a loaded current passes through the cable over an operation period of 5 minutes, expressed as a percentage of that period. For example, if the current is flowing for the whole 5 minutes the duty cycle is 100%, and if the current is flowing for 1 minute the duty cycle is 20%. As conductor temperature varies according to the time in use as well as current, ratings shown are given as a guide.
The permissible loading of the cable for duty cycles other than those shown in the table can be calculated using the following formula: I = I100 x √100/F
Where:
I : is the maximum permissible loading current for the required duty cycle.
I100 : is the maximum permissible loading current for a duty cycle of 100%.
F : is the required duty cycle calculated as a percentage of the 5 minute operation period.
Typical guidance values for different welding processes are as follows:
Fully automatic welding 100%
Semi-automatic welding 65 - 85%
Manual Welding 30 - 60%
Very infrequent or occasional welding 20%

DE-RATING FACTORS

AMBIENT TEMPERATURE 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC
DE-RATING FACTOR 1 0/96 0/91 0/87 0/82 0/76 0/71

اطلاعات ارائه شده در این برگه ، صرفاً جهت راهنمایی مهندسان طراح سیستمهای برق و کاربران است . تمامی اطلاعات با حسن نیت ارائه شده و اعتقاد بر این است که در زمان انتشار صحیح بوده است . هنگام انتخاب تجهیزات جانبی کابل لطفاً توجه داشته باشید که ابعاد واقعی کابل ممکن است به دلیل شرایط تولید متفاوت باشد .
کارشناسان این شرکت با افتخار ، آماده ارائه هرگونه اطلاعات فنی و مهندسی تکمیلی در خصوص این کابل و یا سایر کابلهای مورد نیاز پروژه شما میباشند .