EN 50252-2-41, EN 60228
STANDARDS
APPLICATION
Designed for use in environments where sustained heat resistance and continued function is required. They have heat resistant properties up to 180°C and can also be employed at temperatures as low as -60°C. These cables are halogen free and are particularly suitable for power plants, a wide range of industrial applications in processing, packaging, refrigeration, foundaries, aircraft construction and ship building.
CHARACTERISTICS
Voltage Rating Uo/U : 0.5mm2 to 6mm2 : 300/500V 10mm2 and above: 0.6/1kV, when protected
Temperature Rating : Fixed: -60°C to +180°C
Minimum Bending Radius : Fixed: 4 x overall diameter
CONSTRUCTION
| Conductor : | Class 5 flexible tinnned copper | ||
| Insulation : | Silicone rubber | ||
| Outer Sheath : | Fibre Glass Braid | ||
| Sheath Colour : | Black Blue Brown Red White Grey Violet Pink Orange Yellow Green/Yellow |
||
DIMENSIONS
| NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm2 |
NOMINAL THICKNESS OF INSULATION mm2 |
NOMINAL OVERALL DIAMETER mm |
NOMINAL WEIGHT kg/km |
||
| 1 | 0/25 | 0/55 | 2 | 8 | ||
| 1 | 0/35 | 0/55 | 2/1 | 9 | ||
| 1 | 0/5 | 0/55 | 2/2 | 11 | ||
| 1 | 0/75 | 0/55 | 2/4 | 14 | ||
| 1 | 1 | 0/55 | 2/6 | 17 | ||
| 1 | 1/5 | 0/55 | 2/9 | 22 | ||
| 1 | 2/5 | 0/55 | 3/6 | 37 | ||
| 1 | 4 | 0/8 | 4/4 | 55 | ||
| 1 | 6 | 0/8 | 4/9 | 74 | ||
| 1 | 10 | 1 | 6/3 | 116 | ||
| 1 | 16 | 1 | 7/3 | 172 | ||
| 1 | 25 | 1/2 | 9 | 261 | ||
| 1 | 35 | 1/3 | 10/2 | 354 | ||
| 1 | 50 | 1/4 | 12 | 511 | ||
| 1 | 70 | 1/5 | 14/1 | 725 | ||
| 1 | 95 | 1/7 | 15/8 | 923 | ||
| 1 | 120 | 1/7 | 17/6 | 1189 | ||
| 1 | 150 | 2 | 19/7 | 1464 | ||
| 1 | 185 | 2/2 | 21/8 | 1803 | ||
| 1 | 240 | 2/4 | 24/3 | 2375 | ||
| 1 | 300 | 2/6 | 27/2 | 3020 | ||
CONDUCTORS
Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables
| NOMINAL CROSS SECTIONAL AREA mm2 |
MAXIMUM DIAMETER OF WIRES IN CONDUCTOR mm |
MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC ohms/km |
||||
| Plain Wires | Metal-Coated Wires | |||||
| 0/25 | 0/21 | 83/8 | 86 | |||
| 0/35 | 0/21 | 54/4 | 55/5 | |||
| 0/5 | 0/21 | 39 | 40/1 | |||
| 0/75 | 0/21 | 26 | 26/7 | |||
| 1 | 0/21 | 19/5 | 20 | |||
| 1/5 | 0/26 | 13/3 | 13/7 | |||
| 2/5 | 0/26 | 7/98 | 8/21 | |||
| 4 | 0/31 | 4/95 | 5/09 | |||
| 6 | 0/31 | 3/3 | 3/39 | |||
| 10 | 0/41 | 1/91 | 1/95 | |||
| 16 | 0/41 | 1/21 | 1/24 | |||
| 25 | 0/41 | 0/78 | 0/795 | |||
| 35 | 0/41 | 0/554 | 0/565 | |||
| 50 | 0/41 | 0/386 | 0/393 | |||
| 70 | 0/51 | 0/272 | 0/277 | |||
| 95 | 0/51 | 0/206 | 0/21 | |||
| 120 | 0/51 | 0/161 | 0/164 | |||
| 150 | 0/51 | 0/129 | 0/132 | |||
| 185 | 0/51 | 0/106 | 0/108 | |||
| 240 | 0/51 | 0/0801 | 0/0817 | |||
| 300 | 0/51 | 0/0641 | 0/0654 | |||
Flexible Core Silicone Rubber Insulated Cable / Fibre Glass Braid (SIAF/GL)
| NOMINAL CROSS SECTIONAL AREA mm2 |
CURRENT RATING IN AIR Amps |
|||||
| at 30ºC | at 60ºC | at 90ºC | at 120ºC | at 150ºC | at 170ºC | |
| 0/25 | 15 | 13 | 11 | 9 | 6 | 3 |
| 0/35 | 19 | 17 | 14 | 11 | 7 | 4 |
| 0/5 | 23 | 20 | 17 | 13 | 9 | 5 |
| 0/75 | 30 | 26 | 22 | 17 | 11 | 6 |
| 1 | 35 | 31 | 26 | 20 | 13 | 7 |
| 1/5 | 44 | 38 | 52 | 25 | 17 | 8 |
| 2/5 | 61 | 53 | 45 | 35 | 23 | 12 |
| 4 | 82 | 71 | 60 | 47 | 31 | 16 |
| 6 | 104 | 91 | 77 | 60 | 39 | 20 |
| 10 | 148 | 129 | 108 | 85 | 56 | 28 |
| 16 | 197 | 173 | 145 | 114 | 75 | 58 |
| 25 | 263 | 230 | 193 | 151 | 99 | 51 |
| 35 | 327 | 286 | 240 | 188 | 124 | 63 |
| 50 | 413 | 362 | 304 | 238 | 157 | 80 |
| 70 | 531 | 465 | 391 | 306 | 201 | 103 |
| 95 | 623 | 545 | 458 | 359 | 236 | 121 |
| 120 | 738 | 645 | 543 | 425 | 280 | 143 |
| 150 | 850 | 744 | 626 | 491 | 323 | 166 |
| 185 | 969 | 848 | 214 | 560 | 369 | 190 |
| 240 | 1191 | 1043 | 879 | 689 | 454 | 234 |
| 300 | 1339 | 1173 | 988 | 776 | 512 | 264 |