EN 50525-2-11 Flame Retardant according to IEC/EN 60332-1-2
APPLICATION
این کابل PVC معمولی برای استفاده در لوازم خانگی، آشپزخانه و ادارات، برای استفاده در وسایل سیار سبک مانند چراغ های رومیزی و تجهیزات اداری کاربرد دارند. به طور کلی برای استفاده در فضای باز یا کاربردهای صنعتی نامناسب است.
STANDARDS
CHARACTERISTICS
Voltage Rating Uo/U : 300/500V
Temperature Rating : Flexed: +5°C to +70°C
Minimum Bending Radius : Fixed: 8 x overall diameter
CONSTRUCTION
| Conductor : | Class 5 flexible copper conductor | ||
| Insulation : | PVC (Polyvinyl Chloride) | ||
| Sheath: | PVC (Polyvinyl Chloride) | ||
| Core Identification : | 2 core: Blue Black 3 core: Yellow Red Black 4 core: Yellow Red Black Blue 5 core: Yellow Red Black Blue Green/Yellow |
||
| Sheath Colour : | ●Black ○White | ||
DIMENSIONS
| NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm2 |
NOMINAL THICKNESS OF INSULATION mm |
NOMINAL OVERALL DIAMETER mm |
NOMINAL WEIGHT kg/km |
||
| 2 | 0/75 | 0/6 | 6/3 | 57 | ||
| 2 | 1 | 0/6 | 6/6 | 65 | ||
| 2 | 1/5 | 0/7 | 7/4 | 84 | ||
| 2 | 2/5 | 0/8 | 9/1 | 130 | ||
| 3 | 0/75 | 0/6 | 6/7 | 68 | ||
| 3 | 1 | 0/6 | 7 | 78 | ||
| 3 | 1/5 | 0/7 | 8/1 | 108 | ||
| 3 | 2/5 | 0/8 | 9/9 | 163 | ||
| 3 | 4 | 0/8 | 11/3 | 227 | ||
| 4 | 0/75 | 0/6 | 7/3 | 82 | ||
| 4 | 1 | 0/6 | 7/9 | 100 | ||
| 4 | 1/5 | 0/7 | 9 | 134 | ||
| 4 | 2/5 | 0/8 | 10/8 | 201 | ||
| 5 | 0/75 | 0/6 | 8/1 | 102 | ||
| 5 | 1 | 0/6 | 8/6 | 120 | ||
| 5 | 1/5 | 0/7 | 10 | 166 | ||
CONDUCTORS
Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables
| NOMINAL CROSS SECTIONAL AREA mm2 |
MAXIMUM DIAMETER OF WIRES IN CONDUCTOR mm |
MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C ohms/km |
||||
| Plain Wires | ||||||
| 0/75 | 0/21 | 26 | ||||
| 1 | 0/21 | 19/5 | ||||
| 1/5 | 0/26 | 13/3 | ||||
| 2/5 | 0/26 | 7/98 | ||||
| 4 | 0/31 | 4/95 | ||||
ELECTRICAL CHARACTERISTICS
Current Carrying Capacity and Mass Supportable
| NOMINAL CROSS SECTIONAL AREA mm |
CURRENT CARRYING CAPACITY Amps |
MAXIMUM MASS SUPPORTABLE BY TWIN FLEXIBLE CORD Kg |
||||
| Single-Phase AC | Three-Phase AC | |||||
| 0/75 | 6 | 6 | 3 | |||
| 1 | 10 | 10 | 5 | |||
| 1/5 | 16 | 16 | 5 | |||
| 2/5 | 25 | 20 | 5 | |||
| 4 | 32 | 25 | 5 | |||
VOLTAGE DROP
| NOMINAL CROSS SECTIONAL AREA mm2 |
DC OR SINGLE-PHASE AC mV/A/m |
THREE-PHASE AC mV/A/m |
||||
| 0/75 | 62 | 54 | ||||
| 1 | 46 | 40 | ||||
| 1/5 | 32 | 27 | ||||
| 2/5 | 19 | 16 | ||||
| 4 | 12 | 10 | ||||
Conductor operating temperature: 60ºC
DE-RATING FACTORS
De-Rating Factor for Ambient Temperature 60ºC Thermoplastic or Therm
| AIR TEMPERATURE | 35ºC | 40ºC | 45ºC | 50ºC | 55ºC | |
| DE-RATING FACTOR | 0.91 | 0.82 | 0.71 | 0/58 | 0/41 | |