VDE 0207-303-7, Flame Retardant according to IEC/EN 60332-1-2, IEC/EN 60332-3-24 Low Smoke Zero Halogen according to IEC/EN 60754-1/2, IEC/EN 61034-1/2
APPLICATION
Veriflex low smoke halogen-free flexible connecting cable for instrumentation and control equipment for tooling machinery, production lines, and in flexible applications with free movement and no tensile load. Suitable for use in dry, ambient and wet rooms. These cables are not suitable for outdoor or underground installations..
STANDARDS
CHARACTERISTICS
Voltage Rating Uo/U : 300/500V
Temperature Rating : Fixed: -40°C to +80°C Flexed: -15°C to +70°C
Minimum Bending Radius : Fixed: 6 x overall diameter Flexed: 15 x overall diameter
CONSTRUCTION
Conductor : Class 5 flexible plain copper
Insulation :XLPE (Cross-linked Polyethylene)
Separator : PET (Polyester Tape)
Screen 1 : Al/PET (Aluminium Polyester Tape)
Screen 2 : TCWB (Tinned Copper Wire Braid)
Sheath :LSZH (Low Smoke Zero Halogen)
Core Identification : Black numbered + Green/Yellow
Sheath Colour :Black
DIMENSIONS
| NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm2 |
NOMINAL THICKNESS OF INSULATION mm |
NOMINAL THICKNESS OF OUTER SHEATH mm |
NOMINAL OVERALL DIAMETER mm |
NOMINAL WEIGHT kg/km |
|
| 2 | 0/5 | 0/4 | 0/7 | 4/8 | 36 | |
| 2 | 0/75 | 0/4 | 0/7 | 5/2 | 46 | |
| 2 | 1 | 0/4 | 0/7 | 5/6 | 56 | |
| 2 | 1/5 | 0/4 | 0/8 | 6/4 | 73 | |
| 2 | 2/5 | 0/5 | 0/9 | 7/6 | 113 | |
| 3 | 0/5 | 0/4 | 0/7 | 5/1 | 44 | |
| 3 | 0/75 | 0/4 | 0/7 | 5/5 | 55 | |
| 3 | 1 | 0/4 | 0/8 | 6/1 | 69 | |
| 3 | 1/5 | 0/4 | 0/8 | 6/8 | 91 | |
| 3 | 2/5 | 0/5 | 0/9 | 8/3 | 140 | |
| 3 | 4 | 0/6 | 1 | 10 | 210 | |
| 3 | 6 | 0/65 | 1/1 | 11/5 | 293 | |
| 3 | 10 | 0/75 | 1/4 | 14/9 | 500 | |
| 3 | 16 | 0/75 | 1/5 | 16/8 | 704 | |
| 4 | 0/5 | 0/4 | 0/7 | 5/5 | 54 | |
| 4 | 0/75 | 0/4 | 0/8 | 6/2 | 70 | |
| 4 | 1 | 0/4 | 0/8 | 6/7 | 85 | |
| 4 | 1/5 | 0/4 | 0/9 | 7/6 | 116 | |
| 4 | 2/5 | 0/5 | 1 | 9/3 | 179 | |
| 4 | 4 | 0/6 | 1/1 | 11/2 | 269 | |
| 4 | 6 | 0/65 | 1/2 | 12/8 | 374 | |
| 4 | 10 | 0/75 | 1/5 | 16/6 | 608 | |
| 4 | 16 | 0/75 | 1/6 | 18/7 | 844 | |
| 4 | 25 | 0/9 | 2 | 23/6 | 1327 | |
| 4 | 35 | 0/95 | 2/2 | 27/2 | 1790 | |
| 5 | 0/5 | 0/4 | 0/8 | 6/2 | 64 | |
| 5 | 0/75 | 0/4 | 0/8 | 6/7 | 83 | |
| 5 | 1 | 0/4 | 0/9 | 7/5 | 104 | |
| 5 | 1/5 | 0/4 | 0/9 | 8/3 | 136 | |
| 5 | 2/5 | 0/5 | 1/1 | 10/3 | 213 | |
| 5 | 4 | 0/6 | 1/2 | 12/4 | 321 | |
| 5 | 6 | 0/65 | 1/3 | 14/3 | 447 | |
| 5 | 10 | 0/75 | 1/6 | 18/4 | 760 | |
| 5 | 16 | 0/75 | 1/8 | 20/9 | 1064 | |
| 5 | 25 | 0/9 | 2/2 | 26/4 | 1673 | |
| 7 | 0/5 | 0/4 | 0/8 | 6/7 | 81 | |
| 7 | 0/75 | 0/4 | 0/9 | 7/5 | 108 | |
| 7 | 1 | 0/4 | 0/9 | 8/1 | 130 | |
| 7 | 1/5 | 0/4 | 1 | 9/2 | 177 | |
| 7 | 2/5 | 0/5 | 1/1 | 11/2 | 277 | |
| 7 | 4 | 0/6 | 1/3 | 13/7 | 423 | |
| 7 | 6 | 0/65 | 1/4 | 15/7 | 593 | |
| 8 | 0/5 | 0/4 | 0/9 | 7/5 | 95 | |
| 8 | 1 | 0/4 | 1 | 9 | 150 | |
| 8 | 1/5 | 0/4 | 1 | 10 | 200 | |
| 12 | 0/5 | 0/4 | 1 | 9/1 | 139 | |
| 12 | 0/75 | 0/4 | 1 | 9/9 | 179 | |
| 12 | 1 | 0/4 | 1/1 | 10/9 | 225 | |
| 12 | 1/5 | 0/4 | 1/2 | 12/4 | 302 | |
| 18 | 0/5 | 0/4 | 1/1 | 10/7 | 201 | |
| 18 | 0/75 | 0/4 | 1/2 | 11/9 | 230 | |
| 18 | 1 | 0/4 | 1/2 | 12/9 | 324 | |
| 18 | 1/5 | 0/4 | 1/4 | 14/8 | 446 | |
| 18 | 2/5 | 0/5 | 1/6 | 18/2 | 704 | |
| 25 | 0/5 | 0/4 | 1/2 | 12/9 | 285 | |
| 25 | 0/75 | 0/4 | 0/13 | 14/3 | 372 | |
| 25 | 1 | 0/4 | 1/4 | 15/7 | 462 | |
| 25 | 1/5 | 0/4 | 1/6 | 18 | 627 | |
| 25 | 2/5 | 0/5 | 1/9 | 22/3 | 997 | |
| 34 | 0/75 | 0/4 | 1/5 | 16/3 | 492 | |
| 34 | 1 | 0/4 | 1/6 | 17/9 | 617 | |
| 34 | 1/5 | 0/4 | 1/7 | 20/2 | 833 | |
ELECTRICAL CHARACTERISTICS
| NOMINAL CROSS SECTIONAL AREA mm2 |
CURRENT CARRYING CAPACITES 30°C CONTINOUS LOADING A |
MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C ohms/km |
||||
| 0/5 | 9 | 39 | ||||
| 0/75 | 12 | 26 | ||||
| 1 | 15 | 19/5 | ||||
| 1/5 | 18 | 13/3 | ||||
| 2/5 | 26 | 7/98 | ||||
| 4 | 34 | 4/95 | ||||
| 6 | 44 | 3/3 | ||||
| 10 | 61 | 1/91 | ||||
| 16 | 82 | 1/21 | ||||
| 25 | 108 | 0/78 | ||||
| 35 | 135 | 0/554 | ||||