EN 50525-2-81, EN 60228, HD 22.6, VDE 0282-6, BS 638 Part 4 Flame Retardant according to IEC/EN 60332-1-2
STANDARDS
APPLICATION
These cables are used as a connection to welding robots in the automotive industry, shipyards and for manually/automatically operated lines and spot welding. These cables are ideal for use as an interconnecting battery cable or in battery storage systems. The robust cable structure makes them resistant to low and high temperatures, ozone and radiation, oils, acids, fats and petrols.
CHARACTERISTICS
Voltage Rating : 100V
Temperature Rating : Fixed: -40°C to +85°C Flexed: -20°C to +85°C
Minimum Bending Radius : Fixed: 6 x overall diameter
CONSTRUCTION
Separator :PET (Polyester Tape)
Sheath :Rubber compound
Sheath Colour :Black Red
DIMENSIONS
| NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm2 | NOMINAL THICKNESS OF INSULATION mm | NOMINAL WEIGHT kg/km | ||
|---|---|---|---|---|---|
| 1 | 10 | 2 | 146 | ||
| 1 | 16 | 2 | 204 | ||
| 1 | 25 | 2 | 290 | ||
| 1 | 35 | 2 | 384 | ||
| 1 | 50 | 2.2 | 535 | ||
| 1 | 70 | 2.4 | 716 | ||
| 1 | 95 | 2.6 | 943 | ||
| 1 | 120 | 2.8 | 1,235 | ||
| 1 | 150 | 3 | 1,556 | ||
| CONDUCTORS | ||||
|---|---|---|---|---|
| Flexible Copper Conductors for Single Core Cables | ||||
| NOMINAL CROSS SECTIONAL AREA mm2 | MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC ohms/km | |||
| 10 | 1.91 | |||
| 16 | 1.21 | |||
| 25 | 0.78 | |||
| 35 | 0.55 | |||
| 50 | 0.39 | |||
| 70 | 0.27 | |||
| 95 | 0.21 | |||
| 120 | 0.16 | |||
| 150 | 0.13 | |||
ELECTRICAL CHARACTERISTICS
| NOMINAL CROSS SECTIONAL AREA mm2 | CURRENT RATING FOR SINGLE CYCLE OPERATION OVER A MAXIMUM PERIOD OF 5 MINUTES Amps | ||||||
|---|---|---|---|---|---|---|---|
| 0.85 | 0.35 | ||||||
| 10 | 100 | 103 | 122 | ||||
| 16 | 135 | 145 | 230 | ||||
| 25 | 180 | 195 | 300 | ||||
| 35 | 225 | 245 | 375 | ||||
| 50 | 285 | 305 | 480 | ||||
| 70 | 355 | 385 | 600 | ||||
| 95 | 430 | 470 | 730 | ||||
| 120 | 500 | 540 | 850 | ||||
| 150 | 580 | 630 | 980 | ||||
| Ambient Air Temperature: 25°C Maximum Conductor Temperature: 85°C | |||||||
|---|---|---|---|---|---|---|---|
| Duty Cycle and Current Carrying Capacity The current carrying capacity of a welding cable depends on the length of the duty cycle. The duty cycle is the length of time during which a loaded current passes through the cable over an operation period of 5 minutes, expressed as a percentage of that period. For example, if the current is flowing for the whole 5 minutes the duty cycle is 100%, and if the current is flowing for 1 minute the duty cycle is 20%. As conductor temperature varies according to the time in use as well as current, ratings shown are given as a guide. The permissible loading of the cable for duty cycles other than those shown in the table can be calculated using the following formula: I = I100 x √100/F Where: I : is the maximum permissible loading current for the required duty cycle. I100 : is the maximum permissible loading current for a duty cycle of 100%. F : is the required duty cycle calculated as a percentage of the 5 minute operation period. Typical guidance values for different welding processes are as follows: Fully automatic welding 100% Semi-automatic welding 65 - 85% Manual Welding 30 - 60% Very infrequent or occasional welding 20% | |||||||